Archive for May, 2013

    Flex-arm-large

The Tasca test mule turned 2 years in continual illuminated state this May. That’s 8,760 continuous operating hours in the cold, hot, and messy environment of the shop in which it lives. It gets abused as well, from tossing greasy rags over it to see what happens when airflow over the heat sink is cut off, to blowing coolant on it until it freezes. There have been several lessons learned in this time. For example, lumen depreciation, captured by measuring the fixture’s output, has been negligable. Losses have been less than 1.2% so far, which means the White Optics reflector and anti-reflective glass are doing their job, as is the Bridgelux ES Array LED. Temperature readings taken over this time have not changed anywhere, which indicates the internal construction attaching the thermal slug to the heat sink is durable and reliable. (more…)